Carry out the following procedure after repair works to ensure effee self diagnosis and tilt adjustment. When using the self diagnosis function, confirm that NO DISC is being displayed on the display panel and alsothe optical pickup has not been replaced yet. Carry out the self diagnosis in accordance to the guideline and replace the optical pickup when the current value of the laser drive is above 50.
[NOTE] Measure the value once the POWER button is depressed and power is connected before the equipment warm up (within 3 minutes).
-
When NO DISC is being displayed on the display panel, equipment does not function smoothly, etc.
-
Check the current value of the laser drive. With no disc in the drive, press the Screen Display button on the remote control while pressing the STOP button on the equipment.
-
Implement step 4 if the value is below 50. Replace the optical pickup when the value is above 50. After replacement, implement step 2 again and if the value of the optical pickup is above 40, replace the optical pickup again. There is a possiblityof electrostatic failure during replacement.
-
Carry out tilt adjustment of the optical pickup if the value of the optical pickup before replacement is below 50 or the value of the replaced optical pickup is below 40.
-
Carry out initial setting. Press the > 10 button on the remote control while pressing the STOP button on the equipment. With this, the whole procedure is completed.