NAG Fortran Library, Mark 20

FLW3220D9L - License Managed

Microsoft Windows 98/NT/ME/2000/XP,
NAGWare FTN90 Double Precision

Installer's Note



Contents


1. Introduction

This Installer's Note is essential reading for whoever is responsible for the installation of this implementation of the NAG Fortran Library. It is supplied in printed form to accompany the software, and is also available together with the Users' Note (un.html) in the doc folder of the installed product.

Your attention is drawn to the terms and conditions of the Software Licence regarding the use of NAG software. Any request to use this software other than on the licensed computer must be referred to NAG, as should requests for information about the availability of other implementations.

2. Implementation Provided

2.1. Applicability

This implementation is a compiled, tested, ready-to-use version of the NAG Fortran Library that is considered suitable for operation on the computer systems detailed below:

hardware:         32-bit Intel systems and compatible
operating system: Windows 98/NT/ME/2000/XP
Fortran compiler: NAGWAre FTN90 v2.191 or compatible

2.2. Derivation

This implementation was produced at NAG Ltd., Oxford on the computing system detailed below:

hardware:         Intel Xeon
operating system: Windows 2000
Fortran compiler: NAGWare FTN90 v2.191
compiler options: /fixed
C compiler:       Salford scc v3.0

The entire NAG Fortran Library, Mark 20, was compiled with the default optimization.

This library has been tested using the Basic Linear Algebra Subprograms (BLAS) and linear algebra routines (LAPACK) provided by NAG only. (See the Chapter Introductions for F06, F07 and F08 in the NAG Fortran Library Manual.)

3. Distribution Medium

The software is ordinarily distributed on CD-ROM.

3.1. Contents

The following shows the folder/file organization of the library materials as they will be installed.

                      |-- in.html
                      |-- un.html
            |-- doc --|-- blas_lapack_to_nag.txt
            |         |-- nag_to_blas_lapack.txt
            |         |-- lic_agr.txt
            |
            |         |-- nagbl.dll
            |         |-- naginst.dll
            |-- bin --|-- key_inst.exe
            |         |-- key_rqst.exe
            |         |-- setup.txt
            |
            |-- lib --|-- nagbl.lib
flw3220d9l--|
            |-- interface_blocks --|-- *.mod
            |
            |              |-- source ---|-- ??????e.f
            |              |
            |-- examples --|-- data -----|-- ??????e.d
            |              |
            |              |-- results --|-- ??????e.r
            |
            |              |-- envvars.orig
            |-- batch -----|-- envvars.bat
                           |-- nagex.bat

The following shows the folder/file organization of the PDF documentation materials.

  Manual --|-- html --|-- mark20.html
           |          |
           |          |-- frontmatter --|-- foreword.html
           |          |
           |          |-- genint -------|-- *.html
           |          |
           |          |-- images -------|-- *.*
           |          |
           |          |-- indexes ------|-- *.*
           |          |
           |          |-- toc ----------|-- *.html
           |          |
           |          |-- libdoc.css
           |
           |-- pdf ---|-- * ------------|-- *.pdf

3.2. File Sizes

The files require approximately the following disk space:
compiled libraries:
               nagbl.lib:   13.0 Mb
               nagbl.dll:    9.5 Mb
interface blocks:            724 Kb
example program material:   13.2 Mb
batch files:                  12 Kb
library documentation files:  68 Kb
PDF documentation files:     126 Mb

4. Installation

4.1. Library Installation

You should have Administrator privileges to install this software.

The CD contains an InstallShield SETUP executable file (.EXE) for the library implementation and a Windows Installer package for the manual (manual.msi). Installation of the manual is optional. It may be viewed from the CD or installed onto local disk as described in Section 4.2.

To install the Library insert the CD into your CD drive to display the NAG Library Setup Menu. If the Setup Menu does not appear, run e:\setup.exe where e is the drive letter for your CD drive. Select Install the library, Windows Installer will lead you through the installation.

Installation of the Library requires a license key, which will be provided by NAG. This will either be a `Trial' key, which will allow you to try out the library for a limited period of time, or a `Fully Paid' key which enables use of the library indefinitely on a specific workstation. If you do not have a key, choose the option  Request a license key  and Installer will generate a request (usually saved in the file C:\NagKeyRqst.txt), which may be E-mailed or faxed to NAG (see Appendix). In return NAG will send you a valid license key.

Once in possession of a valid license key, begin the installation process again. You will be prompted for the license key. Once this has been entered the process will continue.

If you later wish to upgrade from a trial to a full license, again select  Request a license key  as above, or else locate and run the utility bin\key_rqst.exe .

Should you need to re-install the license key (for example to replace a trial key), again, begin the installation process, now selecting  [Re]Install the license key , or locate and run the utility bin\key_inst.exe .

Installation will create the shortcut

   Start | Programs | Numerical Algorithms Group | FL20 | NAGWare FTN90 with NAG Lib. Command Prompt

which is originally set to launch the command processor CMD.EXE. On Windows 98 and Me systems, the shortcut must be modified as follows (to modify a shortcut, right-click the Start button, and navigate to the shortcut, right-click it, then select Properties | Shortcut):

  1. Change the command interpreter from ...\CMD.EXE to C:\WINDOWS\COMMAND.COM
  2. Add the argument /E:3072 before the argument /K

The shortcut may then be used to start a command prompt window with the correct environment variables to use the FTN90 compiler with the NAG Fortran Library.

You may wish to copy this shortcut from C:\Documents and Settings\All Users\Start Menu\Programs\Numerical Algorithms Group\FL20 into the folder C:\Documents and Settings\All Users\Start Menu\Programs\Salford Software

4.2. Library Manual PDF Installation

It is not necessary to install the Library manual. Users may access it directly on the distribution CD, or it may be installed on a different workstation or server.

To install the Library manual in PDF insert the CD into your CD drive to display the NAG Library Setup Menu. If the Setup Menu does not display, run e:\setup.exe where e is the drive letter for your CD drive. Select Install the library manual. Alternatively you could run e:\manual.msi. Windows Installer will lead you through the installation.

You may wish to move the PDF documentation files to the same location as that for other NAG products. You are encouraged to make them readily available to users, but in such a way that they are not generally accessible from outside your site.

If you do not already have a copy of Adobe Acrobat Reader for your platform, a free copy can be downloaded from http://www.adobe.com/. Please check this site for availability of a reader for your platform.

Please note that if you are using Adobe Acrobat 4.0 or earlier you might experience some problems when printing documents that contain non-standard characters, such as integral signs, square roots and large brackets. These characters will print correctly using Adobe Acrobat 5.0.

The HTML form of the Essential Introduction contains some mathematical characters that are displayed as question marks by releases of Netscape earlier than 6, but these are displayed correctly by Netscape 6 and Internet Explorer. They may also be viewed via the PDF.

If using Netscape, it might be necessary to re-install Acrobat to ensure that the Acrobat plug-in has been installed. If the plug-in has not been installed, Netscape may copy PDF files to a temporary folder, and then not be able to navigate from there.

4.3. Release to Users

A shortcut to the Users' Note will have been installed under all users'

   Start | Programs | Numerical Algorithms Group | FL20

Another shortcut will have been created if the Library Manual PDF was installed onto local disk. Users who access the software via a mapped drive or file server must also be informed of the location of these documents.

The Users' Note (doc\un.html) should be checked and amended as necessary (particularly Sections 3.1 and 5). Advice on accessing the library in Section 3.1 can be checked by running a few example programs following that advice; a suitable sample would be A02AAF, D01AUF, G05LFF and X03AAF. The installation can also be tested using the script nagex.bat. The Users' Note should then be made available to users directly, or be absorbed into local access information.

The following material should also be made accessible to users:

documentation files:

The FL20\Manual folder contains the online documentation. This should be made available to users, in addition to the following:

doc\blas_lapack_to_nag.txt
doc\nag_to_blas_lapack.txt
compiled libraries - one or more of:
lib\nagbl.lib
bin\nagbl.dll
interface block files:
interface_blocks\*.mod
example program material:
examples\source\??????e.f
examples\data\??????e.d
examples\results\??????e.r
batch\envvars.bat
batch\nagex.bat

Note that the example material has been adapted, if necessary, from that published in the NAG Fortran Library Manual, so that programs are suitable for execution with this implementation with no further changes (but see Section 4.4.2 for comments about possible differences in results obtained). Making the example material directly available to users provides them with easily adaptable templates for their own problems.

4.4. Further Information

4.4.1. Output Unit Dependencies (X04)

Certain NAG routines use explicit WRITE statements to produce output directly. The choice of output unit used can be controlled by using X04AAF and X04ABF, described in the NAG Fortran Library Manual. The defaults for this implementation are given in the Users' Note.

4.4.2. Example Programs

The example results distributed were generated using NAGBL.LIB and the software described in Section 2.2. These example results may not be exactly reproducible if the example programs are run in a slightly different environment (for example, a different Fortran compiler, a different compiler library, different arithmetic hardware, or a different set of BLAS or LAPACK routines). The results which are most sensitive to such differences are: eigenvectors (which may differ by a scalar multiple, often -1, but sometimes complex); numbers of iterations and function evaluations; and residuals and other "small" quantities of the same order as the machine precision.

The "example programs" for the routines in the F06 chapter are not typical example programs and they are not in the Library Manual. They are test programs, which are supplied to sites for use in an installation test of the Library. Some of them take much longer to run than other example programs. Routines which are equivalent to BLAS, are tested twice: once when called by their NAG F06 names, and once when called by their BLAS names.

4.4.3. Maintenance Level

The maintenance level of the library can be determined by writing a simple program to call A00AAF, which prints out details of the implementation, including title and product code, compiler and precision used, mark and maintenance level.

5. Documentation

Each supported NAG Fortran Library site is ordinarily provided with a printed copy of the NAG Fortran Library Introductory Guide. Additional documentation is available for purchase; please refer to the NAG websites or contact your local NAG Response Centre for current prices (see Section 6).

Online documentation is bundled with this implementation. Please see Section 4.2.

6. Support from NAG

(a) Contact with NAG

Queries concerning this document or the implementation generally should be directed initially to your local Advisory Service. If you have difficulty in making contact locally, you can contact NAG directly at one of the addresses given in the Appendix. Users subscribing to the support service are encouraged to contact one of the NAG Response Centres (see below).

(b) NAG Response Centres

The NAG Response Centres are available for general enquiries from all users and also for technical queries from sites with an annually licensed product or support service.

The Response Centres are open during office hours, but contact is possible by fax, email and phone (answering machine) at all times.

When contacting a Response Centre it helps us deal with your enquiry quickly if you can quote your NAG site reference and NAG product code (in this case FLW3220D9L).

(c) NAG Websites

The NAG websites provide information about implementation availability, descriptions of products, downloadable software, product documentation and technical reports. The NAG websites can be accessed at

http://www.nag.co.uk/, http://www.nag.com/ (in North America) or http://www.nag-j.co.jp/ (in Japan)

(d) NAG Electronic Newsletter

If you would like to be kept up to date with news from NAG then please register to receive our free electronic newsletter, which will alert you to special offers, announcements about new products or product/service enhancements, customer stories and NAG's event diary. You can register via one of our websites, or by contacting us at nagnews@nag.co.uk.

7. User Feedback

Many factors influence the way NAG's products and services evolve and your ideas are invaluable in helping us to ensure that we meet your needs. If you would like to contribute to this process we would be delighted to receive your comments. Please contact your local NAG Response Centre (shown below).

Appendix - Contact Addresses

NAG Ltd
Wilkinson House
Jordan Hill Road
OXFORD  OX2 8DR                         NAG Ltd Response Centre
United Kingdom                          email: support@nag.co.uk

Tel: +44 (0)1865 511245                 Tel: +44 (0)1865 311744
Fax: +44 (0)1865 310139                 Fax: +44 (0)1865 310139

NAG Inc
1431 Opus Place, Suite 220
Downers Grove
IL 60515-1362                           NAG Inc Response Center
USA                                     email: infodesk@nag.com

Tel: +1 630 971 2337                    Tel: +1 630 971 2345
Fax: +1 630 971 2706                    Fax: +1 630 971 2706

Nihon NAG KK
Hatchobori Frontier Building 2F
4-9-9
Hatchobori
Chuo-ku
Tokyo
104-0032
Japan
email: help@nag-j.co.jp

Tel: +81 (0)3 5542 6311
Fax: +81 (0)3 5542 6312